Skip to content

Zoned switchable smart glass

DGF Segment. One pane, multiple privacy scenarios.

Independently controlled zones frost only the selected part of the glass. Daylight remains where it is useful and privacy appears exactly where it is needed.

  • up to 5 independent zones
  • ~1 W/m² power consumption
  • APP scenes and control
Footage from a DGF installation Independent zone switching
  • 01Privacy in a selected part of the pane
  • 02Zoning aligned with the architecture
  • 03Each zone controlled separately or as a scene

DGF solution

Do not close the whole space when you do not have to.

DGF zoned switchable smart glass divides the active surface into independent zones. Keep the upper part clear, frost the lower part or create your own sequence without mechanical blinds or extra layers.

We align the zones with framing, furniture lines and the way the room is used. The technology strengthens the interior composition instead of creating an arbitrary pattern.

Best suited to:
  • Medical rooms
  • Bathroom windows
  • Boardrooms
  • Residential glazing

How the solution works

Zoning is not a graphic. It is the electrical map of the pane.

DGF Segment uses the same PDLC principle as Classic, but divides the active layer into independently powered zones. Each zone can be clear or frosted without changing the others. One pane can preserve a view at eye level while screening the lower area beside a desk or bed.

The layout is not created later in an app. Division lines, zone count and connection order are part of glass production, so they must match the final dimensions and architecture. The control interface mirrors the physical pane and combines its states into useful scenes.

Important: zones cannot be moved or added after the glass is manufactured. We first design real usage scenarios, then draw the zoning and release the pane for production.

01

Up to five independent zones

The number of zones follows function and pane proportions, not a catalogue maximum. Two well-justified zones often give better operation and calmer detailing than five arbitrary ones.

02

Each zone has its own circuit

Independence requires planned connections, a controller and labelled wiring. Documentation maps each zone to its channel so commissioning and later service remain clear.

03

A scene combines several decisions

Users do not need to switch zones one by one. A “consultation”, “presentation” or “evening” scene can set several zones to a programmed combination with one command.

04

Division lines work with the interior

The height of a worktop, handrail, window transom or furniture edge suggests natural divisions. Aligning these lines makes the technology read as an intentional architectural decision.

What you gain

Technology that follows the space.

The result is not defined by one parameter. It comes from the right pane, considered controls and installation detailing.

01

Independent zones

Each zone can switch state without frosting the whole pane.

02

Scenes in one action

Saved settings adapt the glass to meetings, focused work or rest.

03

Daylight under control

Clear zones continue to admit daylight while the others provide privacy.

04

Designed zoning

The number and proportions of zones follow the size, purpose and rhythm of the partition.

From concept to commissioning

One point of responsibility. Three clear stages.

  1. 01

    Map the zones

    We define the number, height and order of zones on the final pane size.

  2. 02

    Engineer the circuits

    Each zone receives a controlled connection and a clear control logic.

  3. 03

    Program the scenes

    We group zones into convenient scenes operated by a switch, remote or app.

Space and purpose

Privacy can begin and end exactly where it is needed.

DGF Segment makes sense when users have different needs at different heights or parts of the glass. It is not decorative zoning; it is a tool for managing views.

01

Medical and treatment room

Discretion around the patient, light above

Lower partition zones can stay frosted during an examination while the upper area continues to share light and lets staff remain aware of the surroundings. Another scene can frost the whole pane. Heights follow equipment, patient position and circulation rather than a universal template.

Glass for healthcare
02

Boardroom and executive office

Eye-level screening without closing the whole room

A middle zone can block direct corridor views while the upper one preserves openness. During a confidential meeting one scene switches every zone. The layout needs coordination with table height, seated eye level, door frames and any presentation screen.

Offices and meeting rooms
03

Residential window and bathroom

A screened lower zone with view and light retained

In a ground-floor bathroom or bedroom window the lower zone can maintain privacy while the upper area stays clear. At night the whole pane turns frosted. Before manufacture we assess the frame, moisture conditions, exterior lighting and routes for several controlled circuits.

Residential solutions
Smart glass zone controls in the app
DGF devices in the SUPLA app

A project, not a gadget

The interface mirrors the physical glass zoning.

Control becomes intuitive when the app layout mirrors the physical zones. Users see exactly which part will change and can combine zones into everyday scenes.

View DGF projects

Product specifications

Facts instead of vague promises.

Every pane is technically confirmed for its final dimensions and installation. The values below describe the base product configuration.

Ask about your dimensions
Number of zones up to 5, depending on the project
Controls independent or scene-based
Base glass Opti White Pilkington, 4 mm
Layers EVA 0.8 mm + PDLC layer 0.36 mm
Power 48 V DC
Energy use ~1 W/m²
Size and layout made to project
Typical applications
  • private rooms
  • bathrooms
  • meeting rooms
  • clinics
  • apartments
  • offices

Informed selection

Scenarios first. Then the number and height of zones.

The most common mistake is drawing an impressive pattern without checking how it will be used. A good zoned design can be explained through a few simple scenes and remains intuitive even to a first-time user.

Write down user situations

Who needs privacy, from which direction, at what height and for how long? The answers naturally define zone boundaries.

Limit everyday choices

More zones give flexibility but also more channels and states. In practice we design the smallest number that supports the required scenes.

Coordinate the layout with the structure

Division lines should correspond to frames, façade modules, furniture and views. Their position is confirmed on the final pane drawing.

Retain local operation

An app makes scenes convenient, but a switch by the entrance may be fastest. Local and remote control should be defined with the user.

Questions before a project

Clarify first. Quote second.

Pricing depends on dimensions, pane count, controls and installation. A few answers usually identify the right direction.

01Can the zones have different heights?

Yes. Zone proportions and order are defined by the project and confirmed before production.

02Can all zones switch at once?

Yes. Zones can work independently, in groups or as one saved scene.

03When should the zoning be planned?

Before ordering the glass. The active-layer zoning is part of pane production, so it is based on final dimensions.

04Can zone count or height be changed after manufacture?

No. Zoning is formed in the active layer and sealed into the laminated pane. Before production we approve a drawing with zone dimensions, cable exits and controller-channel assignments.

05Does every zone need a separate switch?

No. Zones can be controlled in an app, grouped into scenes or assigned to multifunction switches. Interface design should minimise daily actions while retaining the required control.

06Is the boundary between zones visible?

The active-layer division is a designed element and may be visible, especially when adjacent zones are in different states. Its exact position is shown on the drawing and aligned with frames and furniture.

07What determines the price of zoned smart glass?

The pane size, number and geometry of zones, independent channels, wiring, controller, scenes, installation and commissioning all matter. More complex zoning and control logic increase the design scope beyond the glass itself.

08Can the zones form any pattern?

Not every layout is feasible. Zoning must account for the active-layer technology, minimum distances, cable exits, pane size and controls. Rather than promise any pattern, we prepare a manufacturable layout that remains clear in everyday use.

09What happens to the zones during a power cut?

Unpowered zones return to the frosted state. The design should confirm whether that default is right for every zone and whether a specific function requires backup power.

Technical consultation

Show us the space. We will select the right glass and controls.

Project and quotation

Tell us about the space. We will respond with a clear next step.

Include indicative dimensions, room type and expected effect. You can also start with a photo or plan sent in your email reply.

Jasionka 954 Aeropolis
36-006 Jasionka

    de_DEGerman